Primary Revenue Metering
Introduction
The Shark® 270 meter is a SCADA ready revenue meter for utility customer metering and distributed generation. It has 0.1% energy accuracy with certification to the ANSI C12.20 0.1 Accuracy Class. The meter’s advanced revenue metering capability includes extensive load profiling, transformer/line loss, and CT/PT compensation. Its advanced power quality monitoring provides up to 512 samples/cycle waveform recording. The Shark® 270 meter’s SCADA capability consists of multiple serial and Ethernet communication ports and multiple protocols, including Modbus, Level 2 DNP3, IEC 61850, and MV90. It is fully compatible with the EnergyPQA.com® AI driven energy management system
Primary Revenue Metering
- Third party certified to ANSI C12.20 2015 and C12.1 2014 0.1 Accuracy Class.
- Third party certified to IEC 62053-22 0.2S.
- Transformer/line loss for accurate customer billing.
- CT/PT compensation to correct for instrument transformer errors.
- Time of Use perpetual calendar.
- KYZ pulse outputs/inputs for delivering or recording pulses.
- Test mode and energy presets.
- Meets utility needs for high accuracy, verifiable metering.
Power Quality Measurement and Analysis
Power Quality Measurement and Analysis
Record Power Quality Waveforms at Critical Locations
- Record up to 512 samples/cycle waveforms for sag, swell, or current fault event.
- Waveform scope for viewing real time voltage and current waveforms.
- CBEMA and SEMI F47 graphs.
- Measure:
- Harmonics.
- Power factor.
- Phase imbalance.
- Symmetrical components.
SCADA Communication Capability
SCADA Communication Capability
- Standard Type 2 ANSI optical port and RS485/KYZ port.
- Optional 10/100BaseT Ethernet port with firewalls, port control, encrypted email with SMTPS, and HTML5-based Web server.
- Optional IEC 61850 Protocol Ethernet port.
- Modbus RTU/ASCII, Modbus TCP/IP, DNP3, and IEC 61850 protocols.
- Optional RS485/RS232 communication port.
Under-glass Wireless Cellular
Collect Energy Data and PQ Waveforms Directly over the Air
- Optional 4G LTE™, Verizon certified wireless cellular.
- Cost-effective solution to supplement or replace costly AMI infrastructure.
- High-speed protocol to program meters and download data.
- Collect data with EIG software or MV90.
- Supports Modbus TCP/IP Protocol.
- Collect metering data and power quality waveforms from the same wireless connection.
- Secure communication using virtual private network infrastructure.
Built-in Expandable I/O
Under-glass I/O Instead of Expansion Modules
- Up to two I/O or communication cards can be installed under-glass.
- Analog output cards offer four channel 0-1 mA or 4-20 mA outputs for RTUs, generating stations, and process control applications.
- Pulse input/output card offers four pulse outputs and four status inputs for pulse counting applications.
- Relay input/output card offers two relay outputs and two status inputs for control, alarm, and status.
- IRIG-B card supports precise time synchronization (coming soon).
- Additional Com cards include Ethernet, serial, and IEC 61850.
- Under-glass I/O greatly simplifies installation, eliminating I/O modules and power supplies.
- Keystone connector and terminal block simplify installation by allowing custom I/O cable length.
Enhanced Cybersecurity
Enhanced Cybersecurity
Protect Critical Metering Data
- Meet your cybersecurity initiatives.
- IP Allow/Block lists.
- Password and username encryption.
- Role-based authorization (user-configurable permission).
- Digital firmware signature.
- Anti-tampering System Events log.
- Port lockdown control, firewalls, and encrypted email (with SMTPS) for Ethernet option.
- Hardware locks and sealing switch to prevent remote tampering.
WYSIWYG Screen Designer
WYSIWYG Screen Designer
Create Custom Screens and UI to Meet Specific Needs
- Three display modes with up to 250 screens.
- Custom screens can display any meter readings.
- Customizable display scaling.
- Display water, gas, and other types of usage.
- Add diagnostic information.
- Provide other critical operational data.
- Use the meter as an aggregator and display total usage.
Rugged Design
Rugged Design
Designed for Long Life and Easy Installation
- Primary surge suppression to protect installed meter.
- Built-in I/O instead of expansion modules.
- Superior Keystone connectors to connect I/O to meter base.
- All I/O uses standard RJ45 wiring, allowing cable lengths to be determined in the field.
- Use EIG’s I/O Terminal Breakout Box Kit (CONN20163) to convert the RJ45 cable connection to an 8-pole terminal receptacle that you can use to connect I/O wiring to your equipment.
S1 Relay Case Retrofit
- Draw out meter cradle for easy testing and replacement.
- Easy-remove hinged paddle to simplify installation.
- NEMA 4X rated for use in outdoor substation control panels.
- One button cover release for simpler installation and testing.
Applications
Applications
- Primary revenue metering.
- Advanced metering infrastructure.
- Customer power quality.
- SCADA substation metering.
- Distributed energy/microgrid.
- Industrial and commercial metering and sub-metering.