Call Us: 866-928-7908

Shark Meter Comparison Chart


Shark 50 Shark 50B Shark 100 Shark 100B Shark 200 Shark 250 Shark 270
shark-50 shark-50b shark-100 shark-100b shark-200 shark-250 shark-270
Typical Application Uses              
  Industrial Panel Boards Commerical Energy Management Systems Utility and Industrial switchgear Commerical Energy Management Systems Utility and Industrial Switchgear Utility and Industrial Switchgear Utility and Industrial Revenue Metering
Basic Measurements and Accuracy
Multifunction Metering (V/A/W/Frequency, etc.))
Accuracy Class (ANSI C12.20) 0.5S 0.5S 0.2S 0.2S 0.2S 0.2S 0.2S
Stated Energy Accuracy % 0.5 0.5 0.2 0.2 0.2 0.2 0.15
Number of 3 phase circuits 1 1 1 1 1 1 1
Frequency Range 45-65 Hz 45-65 Hz 45-65 Hz 45-65 Hz 45-65 Hz 45-65 Hz 45-65 Hz
Calibration Method
AccuMeasure™ Auto-Calibration
Constant Calibration™ Technology
Advanced Revenue Measurements
CT/PT Compensation
Transformer Loss Compensation
Time of Use Perpetual TOU Perpetual TOU
Accuracy Test Pulse
Accuracy Test Mode
Logging
NVRAM Memory Up to 4 MB Up to 128 MB Up to 128 MB
Historial logs 3 8 8
Max Days of Logging, 4 values every 15 min. 1,000 10,000 10,000
Limit Log
I/O Log
PQ Log
System Events Log
ITIC/CBEMA Log *
Max Waveform Sampling 512 samples/cycle 512 samples/cycle 512 samples/cycle
Max Stored Waveform Events (before FIFO) 88 319 319
* Events =>1 Second      
Power Quality
Programmable Alarm Limits
THD
TDD
K-Factor
Harmonic Magnitude
Flicker
IEC 61000 Reporting
Customizable EN 51060 Report
kHz Transient Recording
mhz Transient Recording
Communication Options (S= standard, O=optional)
Optical Port/IrDA Port (1-S) (1-S) (1-S)   (1-S)
RS485 (1-O) (1-S) (1-O) (1-O) (1-S)(1-O) (1-S)(1-O)
RS232 (1-O) (1-O)
RJ45 Ethernet (1-S) (1-O) (1-S) (2-O) (1-O) (1-O)
USB (1-S)
Fiber Optic (1-O) (1-O)
WiFi
Modem
Max. No. of Communication Ports 2 2 3 4 3
Protocols
Modbus RTU/ASCII
Modbus TCP/IP
Simultaneous Modbus Sockets 12 12 12
DNP3 Level 2 Level 2
IEC 61850 (2-O) (2-O) (1-O)
GOOSE
BACnet BACnet MS/TP BACnet/IP
SNMP (simple network management protocol)
SMTP (simple mail transfer protocol) Email on Alarm
Display
Integrated
External
Programmable
I/O
High Speed Digital Inputs
Digital Inputs (8-O) (8-O) (4-O)
Relay Outputs (4-O) (4-O) (4-O)
KYZ (Pulse) Outputs (1-O) (1-O) (1-S)+(8-O) (1-S)+(8-O) (1-S)+(8-O)
Analog Outputs (8-O) (8-O) (8-O)
Status Inputs (8-O) (8-O) (8-O)
Time Synchronization
IRIG-B
NTP
Line Frequency Sync
End of Interval Pulse
Meter Security
Password Control
Multi Level User Passwords
Sealing Switch/Mechanism  
Advanced Cyber Security
Meter Physical Form
Socket Form  
Switchboard
Panel meter
Multi-circuit
Prewired Enclosure
Transducer

How Can We Help?

Give us a call at 866-928-7908 or use this form. [contact-form-7 404 "Not Found"]