EIG Meter Comparison Guide
Select Features
Typical Applications
Physical Features
Display Options
Basic Measurements and Accuracy
Advanced Revenue Measurements
Logging
Power Quality
Other
I/O
Time Synchronization
Cyber Security Features
Communication
Standards Conformity
Power Supply and Environmental
Dimensions
Typical Applications
Utility/Industrial - Power Quality Measurement
Physical Features
Mount vertically or horizontally
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.06
ANSI C12.20 Accuracy Class - 0.1 CL Certified
Current Class - Class 2 or Class 20
Current Fault Recording Peak - 80 A/Class 20
Current Pickup 5 mA/1 mA
Frequency Range - (42.5 - 69.9) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 4
Overload Conditions - 100 A; 10 Sec
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 5 V
Voltage Range Line to Line - (10 - 600) V AC
ANSI C12.20 Accuracy Class - 0.1 CL Certified
Current Class - Class 2 or Class 20
Current Fault Recording Peak - 80 A/Class 20
Current Pickup 5 mA/1 mA
Frequency Range - (42.5 - 69.9) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 4
Overload Conditions - 100 A; 10 Sec
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 5 V
Voltage Range Line to Line - (10 - 600) V AC
Advanced Revenue Measurements
Accuracy Test Pulse - 2
CT and PT Compensation
Energy Presets
Test Mode
Time of Use
Transformer and Line Loss Compensation
CT and PT Compensation
Energy Presets
Test Mode
Time of Use
Transformer and Line Loss Compensation
Logging
I/O Log
Limit Log
Memory (Max.) - 4 GB
PQ Log
Programmable Historical Logs - 8
Stored Waveform Events before FIFO (Max.) - 3199
System Events Log
Limit Log
Memory (Max.) - 4 GB
PQ Log
Programmable Historical Logs - 8
Stored Waveform Events before FIFO (Max.) - 3199
System Events Log
Power Quality
CBEMA and SEMI F47 Monitoring
COMTRADE Waveforms
EN 50160 PQ Reporting
Flicker
Harmonics - 127th Order
IEC 61000-4-30 Class A Ed. 3 Certified
K-Factor
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
TDD
THD
Transient Recording - 50 MHz
Waveform Sampling Rate - 1024 samples/cycle
COMTRADE Waveforms
EN 50160 PQ Reporting
Flicker
Harmonics - 127th Order
IEC 61000-4-30 Class A Ed. 3 Certified
K-Factor
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
TDD
THD
Transient Recording - 50 MHz
Waveform Sampling Rate - 1024 samples/cycle
Other
Custom Modbus Map
End of Interval Pulse
Field Upgrades (V-Switches)
Phasor Measurement Unit (PMU) - P/M
Relay Logic
End of Interval Pulse
Field Upgrades (V-Switches)
Phasor Measurement Unit (PMU) - P/M
Relay Logic
I/O
Analog Inputs (Max.) - 16
Analog Outputs (Max.) - 16
Digital Inputs (Max.) - 40
KYZ Pulse Outputs (Max.) - 8
Relay Outputs (Max.) - 28
Relay Outputs (Max.) - 8
Analog Outputs (Max.) - 16
Digital Inputs (Max.) - 40
KYZ Pulse Outputs (Max.) - 8
Relay Outputs (Max.) - 28
Relay Outputs (Max.) - 8
Time
Synchronization
Synchronization
DNP Time Sync
IRIG-B
Line Frequency Sync
NTP
PTP IEEE-1588
RTC Clock Accuracy - 3.5 ppm
IRIG-B
Line Frequency Sync
NTP
PTP IEEE-1588
RTC Clock Accuracy - 3.5 ppm
Cyber Security Features
128 Bit AES Encryption
Digital Firmware Signature
Encrypted User IDs and Passwords
NERC / CIP Utility Security Protocol Compliance
Password Fail Timeouts
Password Protection
Physical Seals
Programmable Port Control
Programmable Seal Switch
Digital Firmware Signature
Encrypted User IDs and Passwords
NERC / CIP Utility Security Protocol Compliance
Password Fail Timeouts
Password Protection
Physical Seals
Programmable Port Control
Programmable Seal Switch
Communication
2 Separately Addressable Ethernet Ports
ANSI Optical Port
Data Rates - 1 second; 2 to 20; 1 cycle
DHCP
DNP3 Level 2
Email on Alarm
Ethernet Gateway
Fiber Optic Ethernet
GE EGD
IEC 61850
IEC 61850 GOOSE
IPV4
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 6
RJ45 Ethernet - 2
RS485 - 2
RTU Master
SNMP
USB - 1
ANSI Optical Port
Data Rates - 1 second; 2 to 20; 1 cycle
DHCP
DNP3 Level 2
Email on Alarm
Ethernet Gateway
Fiber Optic Ethernet
GE EGD
IEC 61850
IEC 61850 GOOSE
IPV4
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 6
RJ45 Ethernet - 2
RS485 - 2
RTU Master
SNMP
USB - 1
Standards Conformity
ANSI C12.20 0.1 CL
ANSI C62.41
CE Marked - Certified
CISPR 11 Ed. 5.1
CISPR 22 Class A
FCC Part 15; Class B
IEC 61000-4-15
IEC 61000-4-30 Class A Ed. 3 Certified
IEC 61000-6-2
IEC 61000-6-4
IEC 61850 Certification
IEC 62053-22 Class - 0.2S Certified
IEC 62053-23 Reactive Energy Ed. 1
IEC 62586-2
IEEE C37.118 - PMU
REACH/RoHS Compliance
UL 61010-1
ANSI C62.41
CE Marked - Certified
CISPR 11 Ed. 5.1
CISPR 22 Class A
FCC Part 15; Class B
IEC 61000-4-15
IEC 61000-4-30 Class A Ed. 3 Certified
IEC 61000-6-2
IEC 61000-6-4
IEC 61850 Certification
IEC 62053-22 Class - 0.2S Certified
IEC 62053-23 Reactive Energy Ed. 1
IEC 62586-2
IEEE C37.118 - PMU
REACH/RoHS Compliance
UL 61010-1
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - Option 1 (100–240) V AC @ 50/60 Hz or (100-240) V DC; Option 2 (18-60) V DC (24-48 V DC Systems); Option 3 (100-240) V AC @ 50/60 Hz
Power Supply Range - Option 1 (100–240) V AC @ 50/60 Hz or (100-240) V DC; Option 2 (18-60) V DC (24-48 V DC Systems); Option 3 (100-240) V AC @ 50/60 Hz
Dimensions
Case Design - Plastic
Overall Size: 10.74 x 6.74 x 6.91 in/27.28 x 17.12 x 17.55 cm
Overall Size: 10.74 x 6.74 x 6.91 in/27.28 x 17.12 x 17.55 cm
Typical Applications
Utility/Industrial - Power Quality Measurement
Physical Features
Display Mounts into Existing Knockouts
Install Without Cutting Panel
Transducer with Remote Display
Install Without Cutting Panel
Transducer with Remote Display
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.06
ANSI C12.20 Accuracy Class - 0.1 CL
Current Class - Class 20 and 2 in one configuration
Current Fault Recording Peak - 80 A
Current Pickup - 1 mA
Frequency Range - Nominal (42.5 - 69.9) Hz; Wide Band (20 - 500) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 4
Overload Conditions - 100 A; 10 Sec
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 5 V
Voltage Range Line to Line - (20 - 720) V AC
ANSI C12.20 Accuracy Class - 0.1 CL
Current Class - Class 20 and 2 in one configuration
Current Fault Recording Peak - 80 A
Current Pickup - 1 mA
Frequency Range - Nominal (42.5 - 69.9) Hz; Wide Band (20 - 500) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 4
Overload Conditions - 100 A; 10 Sec
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 5 V
Voltage Range Line to Line - (20 - 720) V AC
Advanced Revenue Measurements
Accuracy Test Pulse - 2
Time of Use
Transformer and Line Loss Compensation
Time of Use
Transformer and Line Loss Compensation
Logging
Core Log with 172 Automatic Parameters
I/O Log
Limit Log
Memory (Max.) - 1.2 GB
PQ Log
Programmable Historical Logs - 8
Stored Waveform Events before FIFO (Max.) - 5461
System Events Log
I/O Log
Limit Log
Memory (Max.) - 1.2 GB
PQ Log
Programmable Historical Logs - 8
Stored Waveform Events before FIFO (Max.) - 5461
System Events Log
Power Quality
CBEMA and SEMI F47 Monitoring
EN 50160 PQ Reporting
Flicker
Harmonics - 127th Order
IEC 61000-4-30 Class A Ed. 3 Certified
IEEE 519
K-Factor
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
TDD
THD
Waveform Sampling Rate - 1024 samples/cycle
EN 50160 PQ Reporting
Flicker
Harmonics - 127th Order
IEC 61000-4-30 Class A Ed. 3 Certified
IEEE 519
K-Factor
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
TDD
THD
Waveform Sampling Rate - 1024 samples/cycle
Other
Custom Modbus Map
End of Interval Pulse
Field Upgrades (V-Switches)
Relay Logic
End of Interval Pulse
Field Upgrades (V-Switches)
Relay Logic
I/O
Analog Inputs (Max.) - 32
Analog Outputs (Max.) - 16
Digital Inputs (Max.) - 40
KYZ Pulse Outputs (Max.) - 18
Relay Outputs (Max.) - 16
Analog Outputs (Max.) - 16
Digital Inputs (Max.) - 40
KYZ Pulse Outputs (Max.) - 18
Relay Outputs (Max.) - 16
Time
Synchronization
Synchronization
DNP Time Sync
IRIG-B
Line Frequency Sync
NTP
RTC Clock Accuracy - 20 ppm
IRIG-B
Line Frequency Sync
NTP
RTC Clock Accuracy - 20 ppm
Cyber Security Features
128 Bit AES Encryption
Digital Firmware Signature
Encrypted User IDs and Passwords
NERC / CIP Utility Security Protocol Compliance
Password Fail Timeouts
Password Protection
Physical Seals
Programmable Port Control
Digital Firmware Signature
Encrypted User IDs and Passwords
NERC / CIP Utility Security Protocol Compliance
Password Fail Timeouts
Password Protection
Physical Seals
Programmable Port Control
Communication
2 Separately Addressable Ethernet Ports
Data Rates - 1 second; 2 to 20; 1 cycle
DHCP
DNP3 Level 2
Email on Alarm
Fiber Optic Ethernet
GE EGD
IEC 61850
IEC 61850 GOOSE
IPV4
IPV6
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 6
Number of Simultaneous Communication Connections - 6
RJ45 Ethernet - 1
RS232 - 1
RS485 - 4
RTU Master
Data Rates - 1 second; 2 to 20; 1 cycle
DHCP
DNP3 Level 2
Email on Alarm
Fiber Optic Ethernet
GE EGD
IEC 61850
IEC 61850 GOOSE
IPV4
IPV6
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 6
Number of Simultaneous Communication Connections - 6
RJ45 Ethernet - 1
RS232 - 1
RS485 - 4
RTU Master
Standards Conformity
ANSI C12.20 0.1 CL
CE Marked
CISPR 11
EN/IEC 61000-3-2 Class A
EN/IEC 61000-3-3
ICES 001 2006
IEC 61000-4-15
IEC 61000-4-30 Class A Ed. 3 Certified
IEC 62053-22 Class - 0.2S
IEC 62053-23 Reactive Energy - Class 2 Ed. 1
IEC 62586-2
IEEE 519
REACH/RoHS Compliance
UL 61010-1
CE Marked
CISPR 11
EN/IEC 61000-3-2 Class A
EN/IEC 61000-3-3
ICES 001 2006
IEC 61000-4-15
IEC 61000-4-30 Class A Ed. 3 Certified
IEC 62053-22 Class - 0.2S
IEC 62053-23 Reactive Energy - Class 2 Ed. 1
IEC 62586-2
IEEE 519
REACH/RoHS Compliance
UL 61010-1
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - Option 1 (96-276) V @ 50/60 Hz or DC; Option 2 (18-60) V DC
Power Supply Range - Option 1 (96-276) V @ 50/60 Hz or DC; Option 2 (18-60) V DC
Dimensions
Overall Size - 7.25 x 10.70 x 3.74 in/18.41 x 27.19 x 9.51 cm
Typical Applications
Utility/Industrial - Power Quality Measurement
Physical Features
Display Mounts into Existing Knockouts
Install Without Cutting Panel
Transducer with Remote Display
Install Without Cutting Panel
Transducer with Remote Display
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.06
ANSI C12.20 Accuracy Class - 0.2 CL
Current Class - Class 10; 2; or 0.5 (2 and 0.5 are special order)
Current Fault Recording Peak - 60 A
Current Pickup 5 mA/1 mA
Frequency Range - (20 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 4
Overload Conditions - 100 A; 10 Sec
Sampling Rate - Over 400 samples/cycle
Voltage Range Line to Line - 300 V (Standard; for use with PTs); 600 V (Option G)
ANSI C12.20 Accuracy Class - 0.2 CL
Current Class - Class 10; 2; or 0.5 (2 and 0.5 are special order)
Current Fault Recording Peak - 60 A
Current Pickup 5 mA/1 mA
Frequency Range - (20 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 4
Overload Conditions - 100 A; 10 Sec
Sampling Rate - Over 400 samples/cycle
Voltage Range Line to Line - 300 V (Standard; for use with PTs); 600 V (Option G)
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation
Time of Use
Transformer and Line Loss Compensation
CT and PT Compensation
Time of Use
Transformer and Line Loss Compensation
Logging
I/O Log
Limit Log
Memory (Max.) - 4 MB
PQ Log
Programmable Historical Logs - 2
Stored Waveform Events before FIFO (Max.) - 95
System Events Log
Limit Log
Memory (Max.) - 4 MB
PQ Log
Programmable Historical Logs - 2
Stored Waveform Events before FIFO (Max.) - 95
System Events Log
Power Quality
CBEMA and SEMI F47 Monitoring
COMTRADE Waveforms
EN 50160 PQ Reporting
Flicker
Harmonics - 255th Order
IEC 61000-4-30 Class A Ed. 3
K-Factor
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
TDD
THD
Waveform Sampling Rate - 512 samples/cycle
COMTRADE Waveforms
EN 50160 PQ Reporting
Flicker
Harmonics - 255th Order
IEC 61000-4-30 Class A Ed. 3
K-Factor
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
TDD
THD
Waveform Sampling Rate - 512 samples/cycle
Other
Custom Modbus Map
End of Interval Pulse
Field Upgrades (V-Switches)
Relay Logic
End of Interval Pulse
Field Upgrades (V-Switches)
Relay Logic
I/O
Analog Inputs (Max.) - 32
Analog Outputs (Max.) - 32
Digital Inputs (Max.) - 40
KYZ Pulse Outputs (Max.) - 16
Relay Outputs (Max.) - 16
Analog Outputs (Max.) - 32
Digital Inputs (Max.) - 40
KYZ Pulse Outputs (Max.) - 16
Relay Outputs (Max.) - 16
Time
Synchronization
Synchronization
DNP Time Sync
IRIG-B
Line Frequency Sync
NTP
RTC Clock Accuracy - 20 ppm
IRIG-B
Line Frequency Sync
NTP
RTC Clock Accuracy - 20 ppm
Cyber Security Features
Password Protection
Physical Seals
Programmable Port Control
Programmable Seal Switch
Physical Seals
Programmable Port Control
Programmable Seal Switch
Communication
Data Rates - 1 cycle; 1 second; 200 ms
DHCP
DNP3 Level 2
Email on Alarm
Ethernet Gateway
GE EGD
IPV4
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 4
Number of Simultaneous Communication Connections - 4
RJ45 Ethernet - 1
RS232 - 1
RS485 - 4
RTU Master
DHCP
DNP3 Level 2
Email on Alarm
Ethernet Gateway
GE EGD
IPV4
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 4
Number of Simultaneous Communication Connections - 4
RJ45 Ethernet - 1
RS232 - 1
RS485 - 4
RTU Master
Standards Conformity
ANSI C12.20 0.2 CL
CE Marked
IEC 62053-22 Class - 0.2S
UL 61010-1
CE Marked
IEC 62053-22 Class - 0.2S
UL 61010-1
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - Option 1 120 V AC/DC (-20%) to 230 V AC (+20%); Option 2 24 V DC (-20%) to 48 V DC (+20%)
Power Supply Range - Option 1 120 V AC/DC (-20%) to 230 V AC (+20%); Option 2 24 V DC (-20%) to 48 V DC (+20%)
Dimensions
Overall Size - 3.4H x 7.3W x 10.5L in/8.6 x 18.5 x 26.6 cm
Typical Applications
Utility/Industrial Revenue Metering & Power Quality
Physical Features
Install Without Cutting Panel
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.06
ANSI C12.20 Accuracy Class - 0.2 CL
Current Class - Class 20; 10; or 2
Current Pickup 5 mA/1 mA
Overload Conditions - 100 A; 10 Sec
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 2 V
Voltage Range Line to Line - Option S: 600; Option LV: 120 V
ANSI C12.20 Accuracy Class - 0.2 CL
Current Class - Class 20; 10; or 2
Current Pickup 5 mA/1 mA
Overload Conditions - 100 A; 10 Sec
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 2 V
Voltage Range Line to Line - Option S: 600; Option LV: 120 V
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation
Energy Presets
Test Mode
Time of Use
Transformer and Line Loss Compensation
CT and PT Compensation
Energy Presets
Test Mode
Time of Use
Transformer and Line Loss Compensation
Logging
I/O Log
Limit Log
Memory (Max.) - 4 MB
PQ Log
Programmable Historical Logs - 2
Stored Waveform Events before FIFO (Max.) - 95
System Events Log
Limit Log
Memory (Max.) - 4 MB
PQ Log
Programmable Historical Logs - 2
Stored Waveform Events before FIFO (Max.) - 95
System Events Log
Power Quality
CBEMA and SEMI F47 Monitoring
COMTRADE Waveforms
EN 50160 PQ Reporting
Flicker
Harmonics - 255th Order
IEC 61000-4-30 Class A Ed. 3
K-Factor
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
TDD
THD
Waveform Sampling Rate - 512 samples/cycle
COMTRADE Waveforms
EN 50160 PQ Reporting
Flicker
Harmonics - 255th Order
IEC 61000-4-30 Class A Ed. 3
K-Factor
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
TDD
THD
Waveform Sampling Rate - 512 samples/cycle
Other
Custom Modbus Map
End of Interval Pulse
Field Upgrades (V-Switches)
Relay Logic
End of Interval Pulse
Field Upgrades (V-Switches)
Relay Logic
I/O
Analog Inputs (Max.) - 32
Analog Outputs (Max.) - 32
Digital Inputs (Max.) - 40
KYZ Pulse Outputs (Max.) - 20
Relay Outputs (Max.) - 16
Analog Outputs (Max.) - 32
Digital Inputs (Max.) - 40
KYZ Pulse Outputs (Max.) - 20
Relay Outputs (Max.) - 16
Time
Synchronization
Synchronization
DNP Time Sync
IRIG-B
Line Frequency Sync
RTC Clock Accuracy - 1 second per Month
IRIG-B
Line Frequency Sync
RTC Clock Accuracy - 1 second per Month
Cyber Security Features
Password Protection
Physical Seals
Programmable Port Control
Programmable Seal Switch
Physical Seals
Programmable Port Control
Programmable Seal Switch
Communication
ANSI Optical Port
Data Rates - 1 cycle; 1 second; 200 ms
DHCP
DNP3 Level 2
Email on Alarm
Ethernet Gateway
GE EGD
IPV4
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 5
Number of Simultaneous Communication Connections - 5
RJ45 Ethernet - 1
RS485 - 2
RTU Master
Data Rates - 1 cycle; 1 second; 200 ms
DHCP
DNP3 Level 2
Email on Alarm
Ethernet Gateway
GE EGD
IPV4
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 5
Number of Simultaneous Communication Connections - 5
RJ45 Ethernet - 1
RS485 - 2
RTU Master
Standards Conformity
ANSI C12.20 0.2 CL and C12.1
IEC 60687 Certified
IEC 62053-11
IEC 62053-22 Class - 0.2S Certified
IS 14967
MC Canada Approval
IEC 60687 Certified
IEC 62053-11
IEC 62053-22 Class - 0.2S Certified
IS 14967
MC Canada Approval
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - Option 1 - (102 to 270) V AC/DC @50/60 Hz; Option 2 - (18 to 60) V DC
Power Supply Range - Option 1 - (102 to 270) V AC/DC @50/60 Hz; Option 2 - (18 to 60) V DC
Dimensions
Legacy Switchboard: 16” W x 14” D x 11” H/ 40.64 cm x 35.56 cm x 28 cm
NEMA 4X Rated Cover for Switchboard
Overall Size - Socket: 13” W x 10” D x 11” H/33.02 cm x 25.40 cm x 28 cm
Switchboard (SWB3): H10.37" x W7.85" x D8.97"
Typical Applications
Utility/Industrial Revenue Metering
Physical Features
Install Without Cutting Panel
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.06
ANSI C12.20 Accuracy Class - 0.2 CL
Current Class - Class 20; 10; or 2
Current Pickup 5 mA/1 mA
Number of Current Inputs - 2 or 3 depending on form
Overload Conditions - 100 A; 10 Sec
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 2 V
Voltage Range Line to Line - Option S: 600; Option LV: 120 V
ANSI C12.20 Accuracy Class - 0.2 CL
Current Class - Class 20; 10; or 2
Current Pickup 5 mA/1 mA
Number of Current Inputs - 2 or 3 depending on form
Overload Conditions - 100 A; 10 Sec
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 2 V
Voltage Range Line to Line - Option S: 600; Option LV: 120 V
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation
Energy Presets
Test Mode
Time of Use
Transformer and Line Loss Compensation
CT and PT Compensation
Energy Presets
Test Mode
Time of Use
Transformer and Line Loss Compensation
Logging
I/O Log
Limit Log
Memory (Max.) - 2 MB
Programmable Historical Logs - 2
System Events Log
Limit Log
Memory (Max.) - 2 MB
Programmable Historical Logs - 2
System Events Log
Power Quality
COMTRADE Waveforms
Harmonics - 128th Order
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
THD
Harmonics - 128th Order
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
THD
Other
Custom Modbus Map
End of Interval Pulse
Field Upgrades (V-Switches)
Relay Logic
End of Interval Pulse
Field Upgrades (V-Switches)
Relay Logic
I/O
Analog Inputs (Max.) - 32
Analog Outputs (Max.) - 32
Digital Inputs (Max.) - 40
KYZ Pulse Outputs (Max.) - 20
Relay Outputs (Max.) - 16
Analog Outputs (Max.) - 32
Digital Inputs (Max.) - 40
KYZ Pulse Outputs (Max.) - 20
Relay Outputs (Max.) - 16
Time
Synchronization
Synchronization
DNP Time Sync
IRIG-B
Line Frequency Sync
RTC Clock Accuracy - 1 second per Month
IRIG-B
Line Frequency Sync
RTC Clock Accuracy - 1 second per Month
Cyber Security Features
Password Protection
Physical Seals
Programmable Port Control
Programmable Seal Switch
Physical Seals
Programmable Port Control
Programmable Seal Switch
Communication
ANSI Optical Port
Data Rates - 1 cycle; 1 second; 200 ms
DHCP
DNP3 Level 2
Email on Alarm
Ethernet Gateway
GE EGD
IPV4
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 5
Number of Simultaneous Communication Connections - 5
RJ45 Ethernet - 1
RS485 - 2
RTU Master
Data Rates - 1 cycle; 1 second; 200 ms
DHCP
DNP3 Level 2
Email on Alarm
Ethernet Gateway
GE EGD
IPV4
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 5
Number of Simultaneous Communication Connections - 5
RJ45 Ethernet - 1
RS485 - 2
RTU Master
Standards Conformity
ANSI C12.20 0.2 CL and C12.1
IEC 60687 Certified
IEC 62053-11
IEC 62053-22 Class - 0.2S Certified
IS 14967
MC Canada Approval
IEC 60687 Certified
IEC 62053-11
IEC 62053-22 Class - 0.2S Certified
IS 14967
MC Canada Approval
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - Option 1 - (102 to 270) V AC/DC @50/60 Hz; Option 2 - (18 to 60) V DC
Power Supply Range - Option 1 - (102 to 270) V AC/DC @50/60 Hz; Option 2 - (18 to 60) V DC
Dimensions
Legacy Switchboard: 16” W x 14” D x 11” H/ 40.64 cm x 35.56 cm x 28 cm
NEMA 4X Rated Cover for Switchboard
Overall Size - Socket: 13” W x 10” D x 11” H/33.02 cm x 25.40 cm x 28 cm
Switchboard (SWB3): H10.37" x W7.85" x D8.97"
Typical Applications
Utility/Industrial Revenue Metering
Physical Features
9S; 36S; 45S; 9A; SWB3
Install Without Cutting Panel
Install Without Cutting Panel
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.1
ANSI C12.20 Accuracy Class - 0.1 CL Certified
Current Class - Class 2 or Class 10
Current Pickup - Class 20 (5 mA); Class 2 (1 mA)
Extended Frequency Measurement Accuracy +/- 0.007 Hz
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 10 V AC; programmable
Voltage Range Line to Line - (20 - 721) V
ANSI C12.20 Accuracy Class - 0.1 CL Certified
Current Class - Class 2 or Class 10
Current Pickup - Class 20 (5 mA); Class 2 (1 mA)
Extended Frequency Measurement Accuracy +/- 0.007 Hz
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 10 V AC; programmable
Voltage Range Line to Line - (20 - 721) V
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation
Energy Presets
Test Mode
Time of Use
Transformer and Line Loss Compensation
CT and PT Compensation
Energy Presets
Test Mode
Time of Use
Transformer and Line Loss Compensation
Logging
I/O Log
Limit Log
Memory (Max.) - 128 MB
PQ Log
Programmable Historical Logs - 6
Stored Waveform Events before FIFO (Max.) - 128
System Events Log
Limit Log
Memory (Max.) - 128 MB
PQ Log
Programmable Historical Logs - 6
Stored Waveform Events before FIFO (Max.) - 128
System Events Log
Power Quality
CBEMA and SEMI F47 Monitoring
COMTRADE Waveforms
Harmonics - Up to 40th Order
K-Factor
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
TDD
THD
Waveform Sampling Rate - 512 samples/cycle
COMTRADE Waveforms
Harmonics - Up to 40th Order
K-Factor
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
TDD
THD
Waveform Sampling Rate - 512 samples/cycle
Other
Custom Modbus Map
End of Interval Pulse
Field Upgrades (V-Switches)
Surge Suppression Technology
End of Interval Pulse
Field Upgrades (V-Switches)
Surge Suppression Technology
I/O
Analog Outputs (Max.) - 8
Digital Inputs (Max.) - 4
KYZ Pulse Outputs (Max.) - 9
Pulse Inputs (Max.) - 8
Relay Outputs (Max.) - 4
Digital Inputs (Max.) - 4
KYZ Pulse Outputs (Max.) - 9
Pulse Inputs (Max.) - 8
Relay Outputs (Max.) - 4
Time
Synchronization
Synchronization
DNP Time Sync
IRIG-B
Line Frequency Sync
NTP
RTC Clock Accuracy - Better than 15 seconds per month
IRIG-B
Line Frequency Sync
NTP
RTC Clock Accuracy - Better than 15 seconds per month
Cyber Security Features
Allow/Block Lists
Digital Firmware Signature
Encrypted User IDs and Passwords
Ethernet Card Encryption; Configurable Firewalls; and Digital Firmware Signature
NERC / CIP Utility Security Protocol Compliance
Password Fail Timeouts
Password Protection
Physical Seals
Programmable Port Control
Programmable Seal Switch
Digital Firmware Signature
Encrypted User IDs and Passwords
Ethernet Card Encryption; Configurable Firewalls; and Digital Firmware Signature
NERC / CIP Utility Security Protocol Compliance
Password Fail Timeouts
Password Protection
Physical Seals
Programmable Port Control
Programmable Seal Switch
Communication
2 Separately Addressable Ethernet Ports
ANSI Optical Port
Data Rates - 100 ms and 1 second
DNP3 Level 2
Email on Alarm
IEC 61850
IPV4
IPV6
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 4
Number of Simultaneous Communication Connections (Max.) - 24
RJ45 Ethernet - 2
RS232 - 2
RS485 - 3
Underglass 4G Cellular Modem
ANSI Optical Port
Data Rates - 100 ms and 1 second
DNP3 Level 2
Email on Alarm
IEC 61850
IPV4
IPV6
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 4
Number of Simultaneous Communication Connections (Max.) - 24
RJ45 Ethernet - 2
RS232 - 2
RS485 - 3
Underglass 4G Cellular Modem
Standards Conformity
ANSI C12.18
ANSI C12.20 0.1 CL
CE Marked
FCC Part 15; Class B
IEC 61557-12
IEC 62053-22 Class - 0.2S Certified
IEC 62053-23 Reactive Energy - Class 2 Certified
IEEE C37.90.1
IEEE C62.41
MC Canada Approval
REACH/RoHS Compliance
ANSI C12.20 0.1 CL
CE Marked
FCC Part 15; Class B
IEC 61557-12
IEC 62053-22 Class - 0.2S Certified
IEC 62053-23 Reactive Energy - Class 2 Certified
IEEE C37.90.1
IEEE C62.41
MC Canada Approval
REACH/RoHS Compliance
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - Dependent on voltage form; see brochure
Power Supply Range - Dependent on voltage form; see brochure
Dimensions
Case Design - Plastic
Keystone Connectors for Communication and I/O
Overall Size: Socket Form: H7" x W6.96" x D8.75"; Switchboard Form (SWB3): H10.37" x W7.85" x D8.97"
Keystone Connectors for Communication and I/O
Overall Size: Socket Form: H7" x W6.96" x D8.75"; Switchboard Form (SWB3): H10.37" x W7.85" x D8.97"
Typical Applications
Utility/Industrial
Physical Features
ANSI C39.1 4 in. round or IEC 96 mm DIN square form
Install Without Cutting Panel
Install Without Cutting Panel
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.1
ANSI C12.20 Accuracy Class - 0.1 CL Certified
Current Class - Class 2 or Class 10
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Extended Frequency Measurement Accuracy +/- 0.007 Hz
Frequency Range - (45 - 65) Hz
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 10 V AC; programmable
Voltage Range Line to Line - Absolute Range (0-721) V
ANSI C12.20 Accuracy Class - 0.1 CL Certified
Current Class - Class 2 or Class 10
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Extended Frequency Measurement Accuracy +/- 0.007 Hz
Frequency Range - (45 - 65) Hz
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 10 V AC; programmable
Voltage Range Line to Line - Absolute Range (0-721) V
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation
Energy Presets
Test Mode
Time of Use
Transformer and Line Loss Compensation
CT and PT Compensation
Energy Presets
Test Mode
Time of Use
Transformer and Line Loss Compensation
Logging
I/O Log
Limit Log
Memory (Max.) - 128 MB
PQ Log
Programmable Historical Logs - 6
Stored Waveform Events before FIFO (Max.) - 128
System Events Log
Limit Log
Memory (Max.) - 128 MB
PQ Log
Programmable Historical Logs - 6
Stored Waveform Events before FIFO (Max.) - 128
System Events Log
Power Quality
CBEMA and SEMI F47 Monitoring
COMTRADE Waveforms
Harmonics - Up to 40th Order
K-Factor
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
TDD
THD
Waveform Sampling Rate - 512 samples/cycle
COMTRADE Waveforms
Harmonics - Up to 40th Order
K-Factor
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
TDD
THD
Waveform Sampling Rate - 512 samples/cycle
Other
End of Interval Pulse
Field Upgrades (V-Switches)
I/O
Analog Outputs (Max.) - 8
Digital Inputs (Max.) - 4
KYZ Pulse Outputs (Max.) - 9
Pulse Inputs (Max.) - 8
Relay Outputs (Max.) - 4
Digital Inputs (Max.) - 4
KYZ Pulse Outputs (Max.) - 9
Pulse Inputs (Max.) - 8
Relay Outputs (Max.) - 4
Time
Synchronization
Synchronization
DNP Time Sync
Line Frequency Sync
NTP
RTC Clock Accuracy - 15 seconds per month over the temperature range is the “worst case” scenario - 6 seconds per month is typical at -15 °C to +25 °C.
Line Frequency Sync
NTP
RTC Clock Accuracy - 15 seconds per month over the temperature range is the “worst case” scenario - 6 seconds per month is typical at -15 °C to +25 °C.
Cyber Security Features
Allow/Block Lists
Encrypted User IDs and Passwords
NERC / CIP Utility Security Protocol Compliance
Password Fail Timeouts
Password Protection
Programmable Port Control
Programmable Seal Switch
Encrypted User IDs and Passwords
NERC / CIP Utility Security Protocol Compliance
Password Fail Timeouts
Password Protection
Programmable Port Control
Programmable Seal Switch
Communication
2 Separately Addressable Ethernet Ports
Data Rates - 100 ms and 1 second
DNP3 Level 2
Email on Alarm
Fiber Optic Ethernet
IEC 61850
IPV4
IPV6
IrDA Port
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 4
Number of Simultaneous Communication Connections (Max.) - 24
RJ45 Ethernet - 2
RS232 - 2
RS485 - 1
USB - 1
Data Rates - 100 ms and 1 second
DNP3 Level 2
Email on Alarm
Fiber Optic Ethernet
IEC 61850
IPV4
IPV6
IrDA Port
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 4
Number of Simultaneous Communication Connections (Max.) - 24
RJ45 Ethernet - 2
RS232 - 2
RS485 - 1
USB - 1
Standards Conformity
ANSI C12.20 0.1 CL
CE Marked
IEC 62053-22 Class - 0.2S
IEC 62053-23 Reactive Energy - Class 2
IEEE C37.90.1
IEEE C62.41
REACH/RoHS Compliance
UL 61010-1
CE Marked
IEC 62053-22 Class - 0.2S
IEC 62053-23 Reactive Energy - Class 2
IEEE C37.90.1
IEEE C62.41
REACH/RoHS Compliance
UL 61010-1
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - Option 1 - (90-265) V AC or (100-370) V DC; Option 2 (18-60) V DC
Power Supply Range - Option 1 - (90-265) V AC or (100-370) V DC; Option 2 (18-60) V DC
Dimensions
Case Design - Plastic
DIN-rail Mounted - Transducer Version
Overall Size - H4.85" x W4.85" x D4.25" in.
DIN-rail Mounted - Transducer Version
Overall Size - H4.85" x W4.85" x D4.25" in.
Typical Applications
Utility/Industrial
Physical Features
ANSI C39.1 4 in. round or IEC 96 mm DIN square form
Install Without Cutting Panel
Install Without Cutting Panel
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.2
ANSI C12.20 Accuracy Class - 0.2 CL Certified
Current Class - Class 2 or Class 10
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Extended Frequency Measurement Accuracy +/- 0.007 Hz
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 10 V AC; programmable
Voltage Range Line to Line - Absolute Range (0-721) V
ANSI C12.20 Accuracy Class - 0.2 CL Certified
Current Class - Class 2 or Class 10
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Extended Frequency Measurement Accuracy +/- 0.007 Hz
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 10 V AC; programmable
Voltage Range Line to Line - Absolute Range (0-721) V
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation
Transformer and Line Loss Compensation
CT and PT Compensation
Transformer and Line Loss Compensation
Logging
I/O Log
Limit Log
Memory (Max.) - 4 MB
PQ Log
Programmable Historical Logs - 3
Stored Waveform Events before FIFO (Max.) - 170
System Events Log
Limit Log
Memory (Max.) - 4 MB
PQ Log
Programmable Historical Logs - 3
Stored Waveform Events before FIFO (Max.) - 170
System Events Log
Power Quality
CBEMA and SEMI F47 Monitoring
COMTRADE Waveforms
Harmonics - Up to 40th Order
K-Factor
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
TDD
THD
Waveform Sampling Rate - 512 samples/cycle
COMTRADE Waveforms
Harmonics - Up to 40th Order
K-Factor
Programmable Alarm Alerts
Symmetrical Components and Imbalance (Voltage and Current)
TDD
THD
Waveform Sampling Rate - 512 samples/cycle
Other
End of Interval Pulse
Field Upgrades (V-Switches)
I/O
Analog Outputs (Max.) - 8
Digital Inputs (Max.) - 4
KYZ Pulse Outputs (Max.) - 9
Pulse Inputs (Max.) - 8
Relay Outputs (Max.) - 4
Digital Inputs (Max.) - 4
KYZ Pulse Outputs (Max.) - 9
Pulse Inputs (Max.) - 8
Relay Outputs (Max.) - 4
Time
Synchronization
Synchronization
Line Frequency Sync
NTP
RTC Clock Accuracy - Max. +/-2 seconds per day at 25 °C
NTP
RTC Clock Accuracy - Max. +/-2 seconds per day at 25 °C
Cyber Security Features
Exclusive Client Feature
Password Protection
Programmable Port Control
Password Protection
Programmable Port Control
Communication
2 Separately Addressable Ethernet Ports
Data Rates - Watts; VAR; and VA; 100 ms; All other parameters; 1 second
DNP3
Email on Alarm
Fiber Optic Ethernet
IEC 61850
IPV4
IrDA Port
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 4
Number of Simultaneous Communication Connections (Max.) - 24
RJ45 Ethernet - 2
RS485 - 1
Data Rates - Watts; VAR; and VA; 100 ms; All other parameters; 1 second
DNP3
Email on Alarm
Fiber Optic Ethernet
IEC 61850
IPV4
IrDA Port
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 4
Number of Simultaneous Communication Connections (Max.) - 24
RJ45 Ethernet - 2
RS485 - 1
Standards Conformity
ANSI C12.20 0.2 CL
ANSI C12.41
CE Marked
EN 61000-6-2
EN 61000-6-4
FCC Part 15; Class B
IEC 61850 Certification
IEC 62053-22 Class - 0.2S Certified
IEC 62053-23 Reactive Energy - Class 2
IEEE C37.90.1
IEEE C62.41
NY State Approved for Residential Metering
REACH/RoHS Compliance
UL 61010-1
ANSI C12.41
CE Marked
EN 61000-6-2
EN 61000-6-4
FCC Part 15; Class B
IEC 61850 Certification
IEC 62053-22 Class - 0.2S Certified
IEC 62053-23 Reactive Energy - Class 2
IEEE C37.90.1
IEEE C62.41
NY State Approved for Residential Metering
REACH/RoHS Compliance
UL 61010-1
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - Option 1 - (90-265) V AC or (100-370) V DC; Option 2 (18-60) V DC
Power Supply Range - Option 1 - (90-265) V AC or (100-370) V DC; Option 2 (18-60) V DC
Dimensions
Case Design - Plastic
DIN-rail Mounted - Transducer Version
Overall Size - H4.85" x W4.85" x D4.25" in.
DIN-rail Mounted - Transducer Version
Overall Size - H4.85" x W4.85" x D4.25" in.
Typical Applications
Utility/Industrial
Physical Features
ANSI C39.1 4 in. round or IEC 96 mm DIN square form
Install Without Cutting Panel
Install Without Cutting Panel
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.2
ANSI C12.20 Accuracy Class - 0.2 CL
Current Class - Class 2 or Class 10
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 20 V AC
Voltage Range Line to Line - Absolute Range (0-721) V
ANSI C12.20 Accuracy Class - 0.2 CL
Current Class - Class 2 or Class 10
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 20 V AC
Voltage Range Line to Line - Absolute Range (0-721) V
Advanced Revenue Measurements
Accuracy Test Pulse
Logging
Power Quality
Harmonics - 7th order (current); 3rd order (voltage)
Programmable Alarm Alerts
THD
Programmable Alarm Alerts
THD
Other
Field Upgrades (V-Switches)
I/O
KYZ Pulse Outputs (Max.) - 1
Time
Synchronization
Synchronization
Cyber Security Features
Password Protection
Communication
Data Rates - Watts; VAR; and VA; 100 ms; All other parameters; 1 second
DNP3
IPV4
IrDA Port
Modbus ASCII
Modbus RTU
Modbus TCP/IP
Number of Communication Ports (Max.) - 2
RS485 - 1
DNP3
IPV4
IrDA Port
Modbus ASCII
Modbus RTU
Modbus TCP/IP
Number of Communication Ports (Max.) - 2
RS485 - 1
Standards Conformity
ANSI C12.20 0.2 CL
CE Marked
IEC 62053-22 Class - 0.2S
IEC 62053-23 Reactive Energy - Class 2
IEEE C37.90.1
IEEE C62.41
REACH/RoHS Compliance
UL 61010-1
CE Marked
IEC 62053-22 Class - 0.2S
IEC 62053-23 Reactive Energy - Class 2
IEEE C37.90.1
IEEE C62.41
REACH/RoHS Compliance
UL 61010-1
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - Option 1 - (90-265) V AC or (100-370) V DC; Option 2 (18-60) V DC
Power Supply Range - Option 1 - (90-265) V AC or (100-370) V DC; Option 2 (18-60) V DC
Dimensions
Case Design - Plastic
DIN-rail Mounted - Transducer Version
Overall Size - H4.85" x W4.85" x D4.25" in.
DIN-rail Mounted - Transducer Version
Overall Size - H4.85" x W4.85" x D4.25" in.
Typical Applications
Commercial Energy Management
Physical Features
ANSI C39.1 4 in. round or IEC 96 mm DIN square form
Install Without Cutting Panel
Install Without Cutting Panel
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.2
ANSI C12.20 Accuracy Class - 0.2 CL
Current Class - Class 2 or Class 10
Current Pickup - 5 mA
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 20 V AC
Voltage Range Line to Line - Absolute Range (0-721) V
ANSI C12.20 Accuracy Class - 0.2 CL
Current Class - Class 2 or Class 10
Current Pickup - 5 mA
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 20 V AC
Voltage Range Line to Line - Absolute Range (0-721) V
Advanced Revenue Measurements
Accuracy Test Pulse
Logging
Power Quality
Harmonics - 7th order (current); 3rd order (voltage)
Programmable Alarm Alerts
THD
Programmable Alarm Alerts
THD
Other
I/O
KYZ Pulse Outputs (Max.) - 1
Time
Synchronization
Synchronization
Cyber Security Features
Password Protection
Communication
BACnet/IP
Data Rates - Watts; VAR; and VA; 100 ms; All other parameters; 1 second
IPV4
IrDA Port
Modbus ASCII
Modbus RTU
Modbus TCP/IP
Number of Communication Ports (Max.) - 2
RJ45 Ethernet - 1
Data Rates - Watts; VAR; and VA; 100 ms; All other parameters; 1 second
IPV4
IrDA Port
Modbus ASCII
Modbus RTU
Modbus TCP/IP
Number of Communication Ports (Max.) - 2
RJ45 Ethernet - 1
Standards Conformity
CE Marked
IEC 62053-22 Class - 0.2S
IEC 62053-23 Reactive Energy - Class 2
IEEE C37.90.1
IEEE C62.41
REACH/RoHS Compliance
UL 61010-1
IEC 62053-22 Class - 0.2S
IEC 62053-23 Reactive Energy - Class 2
IEEE C37.90.1
IEEE C62.41
REACH/RoHS Compliance
UL 61010-1
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - Option 1 - (90-265) V AC; Option 2 (18-60) V DC
Power Supply Range - Option 1 - (90-265) V AC; Option 2 (18-60) V DC
Dimensions
Case Design - Plastic
DIN-rail Mounted - Transducer Version
Overall Size - H4.85" x W4.85" x D4.25" in.
DIN-rail Mounted - Transducer Version
Overall Size - H4.85" x W4.85" x D4.25" in.
Typical Applications
Industrial Panel Boards
Physical Features
ANSI C39.1 4 in. round or IEC 96 mm DIN square form
Install Without Cutting Panel
Install Without Cutting Panel
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.5
ANSI C12.20 Accuracy Class - 0.5 CL
Current Class - Class 10
Current Pickup - 5 mA
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 20 V AC
Voltage Range Line to Line - (20 - 721) V
ANSI C12.20 Accuracy Class - 0.5 CL
Current Class - Class 10
Current Pickup - 5 mA
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 20 V AC
Voltage Range Line to Line - (20 - 721) V
Advanced Revenue Measurements
Logging
Power Quality
Other
Field Upgrades (V-Switches)
I/O
KYZ Pulse Outputs (Max.) - 1
Time
Synchronization
Synchronization
Cyber Security Features
Password Protection
Communication
Data Rates - 1 second
IPV4
Modbus ASCII
Modbus RTU
Number of Communication Ports (Max.) - 1
Number of Simultaneous Communication Connections - 1
RS485 - 1
IPV4
Modbus ASCII
Modbus RTU
Number of Communication Ports (Max.) - 1
Number of Simultaneous Communication Connections - 1
RS485 - 1
Standards Conformity
ANSI C12.20 0.5 CL
CE Marked
IEC 62053-22 Class - 0.5S Certified
IEEE C37.90.1
IEEE C62.41
REACH/RoHS Compliance
UL 61010-1
CE Marked
IEC 62053-22 Class - 0.5S Certified
IEEE C37.90.1
IEEE C62.41
REACH/RoHS Compliance
UL 61010-1
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - (90-265) V AC
Power Supply Range - (90-265) V AC
Dimensions
Case Design - Plastic
Overall Size - H4.85" x W4.85" x D4.25" in.
Overall Size - H4.85" x W4.85" x D4.25" in.
Typical Applications
Commercial Energy Management
Physical Features
ANSI C39.1 4 in. round or IEC 96 mm DIN square form
Install Without Cutting Panel
Install Without Cutting Panel
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.5
ANSI C12.20 Accuracy Class - 0.5 CL
Current Class - Class 10
Current Pickup - 5 mA
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 20 V AC
Voltage Range Line to Line - Absolute Range (0-721) V
ANSI C12.20 Accuracy Class - 0.5 CL
Current Class - Class 10
Current Pickup - 5 mA
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 20 V AC
Voltage Range Line to Line - Absolute Range (0-721) V
Advanced Revenue Measurements
Accuracy Test Pulse
Logging
Power Quality
Other
I/O
Time
Synchronization
Synchronization
Cyber Security Features
Password Protection
Communication
BACnet MS/TP
Data Rates - all parameters every 60 cycles
IPV4
Modbus RTU
Modbus TCP/IP
Number of Communication Ports (Max.) - 2
RJ45 Ethernet - 1
RS485 - 1
Data Rates - all parameters every 60 cycles
IPV4
Modbus RTU
Modbus TCP/IP
Number of Communication Ports (Max.) - 2
RJ45 Ethernet - 1
RS485 - 1
Standards Conformity
CE Marked
IEC 62053-22 Class - 0.5S Certified
IEEE C37.90.1
IEEE C62.41
REACH/RoHS Compliance
UL 61010-1
IEC 62053-22 Class - 0.5S Certified
IEEE C37.90.1
IEEE C62.41
REACH/RoHS Compliance
UL 61010-1
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - (90-265) V AC
Power Supply Range - (90-265) V AC
Dimensions
Case Design - Plastic
DIN-rail Mounted - Transducer Version
Overall Size - H4.85" x W4.85" x D4.25" in.
DIN-rail Mounted - Transducer Version
Overall Size - H4.85" x W4.85" x D4.25" in.
Typical Applications
Commercial Submetering
Physical Features
Wall Mountable
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.2
ANSI C12.20 Accuracy Class - 0.2 CL Certified
Current Class - Class 2 or Class 10
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Extended Frequency Measurement Accuracy +/- 0.007 Hz
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Overload Conditions - 100 A; 10 Sec
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 10 V AC
Voltage Range Line to Line - (0 - 721) V
ANSI C12.20 Accuracy Class - 0.2 CL Certified
Current Class - Class 2 or Class 10
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Extended Frequency Measurement Accuracy +/- 0.007 Hz
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Overload Conditions - 100 A; 10 Sec
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 10 V AC
Voltage Range Line to Line - (0 - 721) V
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation
Transformer and Line Loss Compensation
CT and PT Compensation
Transformer and Line Loss Compensation
Logging
Limit Log
Memory (Max.) - 2 MB
Programmable Historical Logs - 3
System Events Log
Memory (Max.) - 2 MB
Programmable Historical Logs - 3
System Events Log
Power Quality
Programmable Alarm Alerts
Other
I/O
Time
Synchronization
Synchronization
Line Frequency Sync
Cyber Security Features
Password Protection
Communication
Data Rates - 100 ms and 1 second
DNP3
IPV4
IrDA Port
Modbus ASCII
Modbus RTU
Modbus TCP/IP
Number of Communication Ports (Max.) - 3
Number of Simultaneous Communication Connections - 2
RJ45 Ethernet - 1
RS485 - 1
WiFi - 802.11 WiFi
DNP3
IPV4
IrDA Port
Modbus ASCII
Modbus RTU
Modbus TCP/IP
Number of Communication Ports (Max.) - 3
Number of Simultaneous Communication Connections - 2
RJ45 Ethernet - 1
RS485 - 1
WiFi - 802.11 WiFi
Standards Conformity
ANSI C12.20 0.2 CL and C12.1 Certified
ANSI C62.41
CE Marked
FCC Part 15; Class B
IEC 62053-22 Class - 0.2S Certified
IEC 62053-23 Reactive Energy - Class 2 Ed. 1
IEEE C37.90.1
IEEE C62.41
REACH/RoHS Compliance
UL 61010-1
ANSI C62.41
CE Marked
FCC Part 15; Class B
IEC 62053-22 Class - 0.2S Certified
IEC 62053-23 Reactive Energy - Class 2 Ed. 1
IEEE C37.90.1
IEEE C62.41
REACH/RoHS Compliance
UL 61010-1
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - (90 to 400) V AC or (100 to 370) V DC; Universal AC/DC Supply
Power Supply Range - (90 to 400) V AC or (100 to 370) V DC; Universal AC/DC Supply
Dimensions
Case Design - Plastic
Overall Size - H7.90" x W7.53" x D3.11"
Overall Size - H7.90" x W7.53" x D3.11"
Typical Applications
Commercial Submetering
Physical Features
Wall Mountable
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.2
ANSI C12.20 Accuracy Class - 0.2 CL
Current Class - Class 2 or Class 10
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Overload Conditions - 100 A; 10 Sec
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 10 V AC
Voltage Range Line to Line - (0 - 721) V
ANSI C12.20 Accuracy Class - 0.2 CL
Current Class - Class 2 or Class 10
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Overload Conditions - 100 A; 10 Sec
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 10 V AC
Voltage Range Line to Line - (0 - 721) V
Advanced Revenue Measurements
Accuracy Test Pulse
Logging
Power Quality
Harmonics - 7th order (current); 3rd order (voltage)
Programmable Alarm Alerts
THD
Programmable Alarm Alerts
THD
Other
Field Upgrades (V-Switches)
I/O
Time
Synchronization
Synchronization
Cyber Security Features
Password Protection
Communication
Data Rates - 100 ms and 1 second
DNP3
IPV4
IrDA Port
Modbus ASCII
Modbus RTU
Modbus TCP/IP
Number of Communication Ports (Max.) - 3
Number of Simultaneous Communication Connections - 2
RJ45 Ethernet - 1
RS485 - 1
WiFi - 802.11 WiFi
DNP3
IPV4
IrDA Port
Modbus ASCII
Modbus RTU
Modbus TCP/IP
Number of Communication Ports (Max.) - 3
Number of Simultaneous Communication Connections - 2
RJ45 Ethernet - 1
RS485 - 1
WiFi - 802.11 WiFi
Standards Conformity
ANSI C12.20 0.2 CL
CE Marked
IEC 62053-22 Class - 0.2S
IEC 62053-23 Reactive Energy - Class 2 Ed. 1
IEEE C37.90.1
IEEE C62.41
REACH/RoHS Compliance
UL 61010-1
CE Marked
IEC 62053-22 Class - 0.2S
IEC 62053-23 Reactive Energy - Class 2 Ed. 1
IEEE C37.90.1
IEEE C62.41
REACH/RoHS Compliance
UL 61010-1
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - (90 to 400) V AC or (100 to 370) V DC; Universal AC/DC Supply
Power Supply Range - (90 to 400) V AC or (100 to 370) V DC; Universal AC/DC Supply
Dimensions
Case Design - Plastic
Overall Size - H7.90" x W7.53" x D3.11"
Overall Size - H7.90" x W7.53" x D3.11"
Typical Applications
Multi-circuit Submetering
Physical Features
Multi-circuit Design
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.5
ANSI C12.20 Accuracy Class - 0.5 CL
Current Class - Class 2 or Class 10
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 8
Number of Current Inputs - 24
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 20 V AC
Voltage Range Line to Line - Absolute Range (0-721) V
ANSI C12.20 Accuracy Class - 0.5 CL
Current Class - Class 2 or Class 10
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Frequency Range - (45 - 65) Hz
Number of 3 Phase Circuits - 8
Number of Current Inputs - 24
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 20 V AC
Voltage Range Line to Line - Absolute Range (0-721) V
Advanced Revenue Measurements
Accuracy Test Pulse
Logging
I/O Log
Limit Log
Memory (Max.) - 32 MB
Programmable Historical Logs - 2
System Events Log
Limit Log
Memory (Max.) - 32 MB
Programmable Historical Logs - 2
System Events Log
Power Quality
Programmable Alarm Alerts
Other
Field Upgrades (V-Switches)
I/O
KYZ Inputs (Max.) - 4
Relay Outputs (Max.) - 2
Relay Outputs (Max.) - 2
Time
Synchronization
Synchronization
RTC Clock Accuracy - ±3.5 ppm max. (±0.3024 second/day) over the rated temperature range
Cyber Security Features
Password Protection
Communication
Data Rates - 1 second
IPV4
Modbus ASCII
Modbus RTU
Modbus TCP/IP
Number of Communication Ports (Max.) - 4
Number of Simultaneous Communication Connections - 3
RJ45 Ethernet - 1
RS485 - 2
USB - 1
WiFi - 802.11 WiFi
IPV4
Modbus ASCII
Modbus RTU
Modbus TCP/IP
Number of Communication Ports (Max.) - 4
Number of Simultaneous Communication Connections - 3
RJ45 Ethernet - 1
RS485 - 2
USB - 1
WiFi - 802.11 WiFi
Standards Conformity
ANSI C12.20 0.5 CL
CE Marked
IEC 62053-22 Class - 0.5S
REACH/RoHS Compliance
UL 61010-1
CE Marked
IEC 62053-22 Class - 0.5S
REACH/RoHS Compliance
UL 61010-1
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - (90-300) V AC @ 50/60 Hz
Power Supply Range - (90-300) V AC @ 50/60 Hz
Dimensions
Overall Size - H7.60" x W11.28" x D3.18"
Typical Applications
Commercial/Industrial Submetering
Physical Features
Compact Size; DIN-rail Mounting
Display Options
Basic Measurements and Accuracy
% Energy Accuracy - 0.2
ANSI C12.20 Accuracy Class - 0.2 CL
Current Class - Class 2 or Class 10
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Frequency Range - (45 - 65) Hz
mV CTs - 0.333 V or Rogowski Coil CTs
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 20 V AC
Voltage Range Line to Line - Absolute Range (0-721) V
ANSI C12.20 Accuracy Class - 0.2 CL
Current Class - Class 2 or Class 10
Current Pickup - Class 10 (5 mA); Class 2 (1 mA)
Frequency Range - (45 - 65) Hz
mV CTs - 0.333 V or Rogowski Coil CTs
Number of 3 Phase Circuits - 1
Number of Current Inputs - 3
Sampling Rate - Over 400 samples/cycle
Voltage Pickup - 20 V AC
Voltage Range Line to Line - Absolute Range (0-721) V
Advanced Revenue Measurements
Accuracy Test Pulse
CT and PT Compensation
Transformer and Line Loss Compensation
CT and PT Compensation
Transformer and Line Loss Compensation
Logging
Limit Log
Memory - Extensive Memory
Programmable Historical Logs - 3
Stored Waveform Events before FIFO (Max.) - 128
System Events Log
Memory - Extensive Memory
Programmable Historical Logs - 3
Stored Waveform Events before FIFO (Max.) - 128
System Events Log
Power Quality
CBEMA and SEMI F47 Monitoring
Harmonics - 40th Order
Programmable Alarm Alerts
THD
Waveform Sampling Rate - 512 samples/cycle
Harmonics - 40th Order
Programmable Alarm Alerts
THD
Waveform Sampling Rate - 512 samples/cycle
Other
Field Upgrades (V-Switches)
I/O
Time
Synchronization
Synchronization
Line Frequency Sync
RTC Clock Accuracy - Max. +/-2 seconds per day at 25 °C
RTC Clock Accuracy - Max. +/-2 seconds per day at 25 °C
Cyber Security Features
Password Protection
Communication
BACnet/IP
Data Rates - 100 ms and 1 second
DNP3
IPV4
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 2
Number of Simultaneous Communication Connections - 3
RJ45 Ethernet - 1
RS485 - 1
USB - 1
Data Rates - 100 ms and 1 second
DNP3
IPV4
Modbus ASCII
Modbus RTU
Modbus TCP/IP
MV90 Support
Number of Communication Ports (Max.) - 2
Number of Simultaneous Communication Connections - 3
RJ45 Ethernet - 1
RS485 - 1
USB - 1
Standards Conformity
ANSI C12.20 0.2 CL
CE Marked
IEC 62053-22 Class - 0.2S
REACH/RoHS Compliance
UL 61010-1
CE Marked
IEC 62053-22 Class - 0.2S
REACH/RoHS Compliance
UL 61010-1
Power Supply and Environmental
Humidity - Up to 95% RH non-condensing
Power Supply Range - (90-300) V AC @ 50/60 Hz
Power Supply Range - (90-300) V AC @ 50/60 Hz
Dimensions
Case Design - Plastic
Overall Size - H4.60" x W4.77" x D2.44"
Overall Size - H4.60" x W4.77" x D2.44"